1 <?xml version='1.0' encoding="UTF-8"?>
2 <!DOCTYPE guide SYSTEM "/dtd/guide.dtd">
3 <guide link="power-management-guide.xml">
4 <title>Power Management Guide</title>
5
6 <author>
7 <mail link="fragfred@gmx.de">Dennis Nienh&#252;ser</mail>
8 </author>
9
10 <abstract>
11 Power Management is the key to extend battery run time on mobile systems like
12 laptops. This guide assists you setting it up on your laptop.
13 </abstract>
14
15 <!-- The content of this document is licensed under the CC-BY-SA license -->
16 <!-- See http://creativecommons.org/licenses/by-sa/2.0 -->
17 <license/>
18
19 <version>1.15</version>
20 <date>August 29, 2004</date>
21
22 <chapter>
23 <title>Introduction</title>
24
25 <section>
26 <title>Why Power Management?</title>
27
28 <body>
29
30 <p>
31 Capacity and lifetime of laptop batteries has improved much in the last years.
32 Nevertheless modern processors consume much more energy than older ones and
33 each laptop generation introduces more devices hungry for energy. That's why
34 Power Management is more important than ever. Increasing battery run time
35 doesn't necessarily mean buying another battery. Much can be achieved applying
36 intelligent Power Management policies.
37 </p>
38
39 </body>
40 </section>
41
42 <section>
43 <title>A quick overview</title>
44 <body>
45
46 <p>
47 Please notice that this guide describes Power Management for <e>laptops</e>.
48 While some sections might also suite for <e>servers</e>, others do not and may
49 even cause harm. Please do not apply anything from this guide to a server
50 unless you really know what you are doing.
51 </p>
52
53 <p>
54 As this guide has become rather long, here's a short overview helping you to
55 find your way through it.
56 </p>
57
58 <p>
59 The <e>Prerequisites</e> chapter talks about some requirements that should be
60 met before any of the following device individual sections will work. This
61 includes BIOS settings, kernel configuration and some simplifications in user
62 land. The following three chapters focus on devices that typically consume most
63 energy - processor, display and hard drive. Each can be configured seperately.
64 <e>CPU Power Management</e> shows how to adjust the processor's frequency to
65 save a maximum of energy whithout losing too much performance. A few different
66 tricks prevent your hard drive from working unnecessarily often in <e>Disk Power
67 Management</e> (decreasing noise level as a nice side effect). Some notes on
68 Wireless LAN and USB finish the device section in <e>Power Management for other
69 devices</e> while another chapter is dedicated to the (rather experimental)
70 <e>sleep states</e>. Last not least <e>Troubleshooting</e> lists common
71 pitfalls.
72 </p>
73
74 </body>
75 </section>
76
77 <section>
78 <title>Power Budget for each component</title>
79 <body>
80
81 <figure link="/images/energy-budget.png" short="Which component consumes how
82 much energy?" caption="Power budget for each component"/>
83
84 <p>
85 Nearly every component can operate in different states - off, sleep, idle,
86 active to name a few - consuming a different amount of energy. Major parts are
87 consumed by the LCD display, CPU, chipset and hard drives. Often one is able to
88 activate OS-independent Power Management in the BIOS, but an intelligent setup
89 in the operating system adapting to different situations can achieve much more.
90 </p>
91
92 </body>
93 </section>
94 </chapter>
95
96 <chapter>
97 <title>Prerequisites</title>
98 <section>
99 <title>What has to be done first</title>
100 <body>
101
102 <p>
103 Before going into the details on making individual devices Power Management
104 aware, make sure certain requirements are met. After controlling the BIOS
105 settings, some kernel options want to be enabled - these are in short ACPI,
106 sleep states and CPU frequency scaling. As power saving most of the time comes
107 along with performance loss or increased latency, it should only be enabled
108 when running on batteries. That's where a new runlevel <e>battery</e> comes in
109 handy.
110 </p>
111
112 </body>
113 </section>
114 <section>
115 <title>The BIOS part</title>
116 <body>
117
118 <p>
119 First have a look into your BIOS Power Management settings. The best way is to
120 combine BIOS and operating system policies, but for the moment it's better to
121 disable most of the BIOS part. This makes sure it doesn't interfere with your
122 policies. Don't forget to re-check BIOS settings after you configured
123 everything else.
124 </p>
125
126 </body>
127 </section>
128 <section>
129 <title>Configuring the kernel</title>
130 <body>
131
132 <p>
133 ACPI (Advanced Configuration and Power Interface) support in the kernel is
134 still work in progress. Using a recent kernel will make sure you'll get the
135 most out of it.
136 </p>
137
138 <p>
139 In kernel config, activate at least these options:
140 </p>
141
142 <pre caption="Minimum kernel setup for Power Management (Kernel 2.6)">
143 Power Management Options ---&gt;
144 [*] Power Management Support
145 [ ] Software Suspend
146 [ ] Suspend-to-Disk Support
147
148 ACPI( Advanced Configuration and Power Interface ) Support ---&gt;
149 [*] ACPI Support
150 [ ] Sleep States
151 &lt;M&gt; AC Adapter
152 &lt;M&gt; Battery
153 &lt;M&gt; Button
154 &lt;M&gt; Fan
155 &lt;M&gt; Processor
156 &lt;M&gt; Thermal Zone
157 &lt; &gt; ASUS/Medion Laptop Extras
158 &lt; &gt; Toshiba Laptop Extras
159 [ ] Debug Statements
160
161 CPU Frequency Scaling ---&gt;
162 [*] CPU Frequency scaling
163 Default CPUFreq governor (userspace)
164 &lt;*&gt; 'performance' governor
165 &lt;*&gt; 'powersave' governor
166 &lt;*&gt; CPU frequency table helpers
167 &lt;M&gt; ACPI Processor P-States driver
168 &lt;*&gt; <i>CPUFreq driver for your processor</i>
169 </pre>
170
171 <p>
172 Decide yourself whether you want to enable Software Suspend, Suspend-to-Disk
173 and Sleep States (see below). If you own an ASUS, Medion or Toshiba laptop,
174 enable the appropriate section.
175 </p>
176
177 <p>
178 Compile your kernel, make sure the right modules get loaded at startup and boot
179 into your new ACPI-enabled kernel. Next run <c>emerge sys-apps/acpid</c> to get
180 the acpi daemon. This one informs you about events like switching from AC to
181 battery or closing the lid. Make sure the module <e>button</e> is loaded if you
182 didn't compile it into the kernel and start acpid with <c>/etc/init.d/acpid
183 start</c>. Run <c>rc-update add acpid default</c> to load it on startup. You'll
184 soon see how to use it.
185 </p>
186
187 <pre caption="Installing acpid">
188 # <i>emerge sys-apps/acpid</i>
189 # <i>modprobe button</i>
190 # <i>/etc/init.d/acpid start</i>
191 # <i>rc-update add acpid default</i>
192 </pre>
193
194 </body>
195 </section>
196 <section>
197 <title>Creating a "battery" runlevel</title>
198 <body>
199
200 <p>
201 The default policy will be to enable Power Management only when needed -
202 running on batteries. To make the switch between AC and battery convenient,
203 create a runlevel <e>battery</e> that holds all the scripts starting and
204 stopping Power Management.
205 </p>
206
207 <note>
208 You can safely skip this section if you don't like the idea of having another
209 runlevel. However, skipping this step will make the rest a bit trickier to set
210 up. The next sections assume a runlevel <e>battery</e> exists.
211 </note>
212
213 <pre caption="Creating a battery runlevel">
214 # <i>cd /etc/runlevels</i>
215 # <i>cp -a default battery</i>
216 </pre>
217
218 <p>
219 Finished. Your new runlevel <e>battery</e> contains everything like
220 <e>default</e>, but there is no automatic switch between both yet. Time to
221 change it.
222 </p>
223
224 </body>
225 </section>
226 <section>
227 <title>Reacting on ACPI events</title>
228 <body>
229
230 <p>
231 Typical ACPI events are closing the lid, changing the power source or pressing
232 the sleep button. Every acpi event recognized by the kernel is catched by acpid
233 which calls <path>/etc/acpi/default.sh</path>. Here is a basic modification
234 supporting runlevel switching:
235 </p>
236
237 <pre caption="Event driven runlevel switching with acpid">
238 #!/bin/sh
239
240 set $*
241
242 group=${1/\/*/}
243 action=${1/*\//}
244
245 <comment># runlevel to use in AC mode</comment>
246 RLVL_AC="default"
247 <comment># runlevel to use in battery mode</comment>
248 RLVL_BATTERY="battery"
249
250 <comment># file indicating the AC state</comment>
251 AC_STATE="/proc/acpi/ac_adapter/AC/state"
252 <comment># this string means running on AC</comment>
253 AC_ON="on-line"
254 <comment># this string means running on batteries</comment>
255 AC_OFF="off-line"
256
257 function SwitchRunlevel() {
258 if [[ "$(grep ${AC_OFF} ${AC_STATE})" != "" &amp;&amp; "$(cat /var/lib/init.d/softlevel)" != "${RLVL_BATTERY}" ]]
259 then
260 logger "Switching to ${RLVL_BATTERY} runlevel"
261 /sbin/rc ${RLVL_BATTERY}
262 elif [[ "$(grep ${AC_ON} ${AC_STATE})" != "" &amp;&amp; "$(cat /var/lib/init.d/softlevel)" != "${RLVL_AC}" ]]
263 then
264 logger "Switching to ${RLVL_AC} runlevel"
265 /sbin/rc ${RLVL_AC}
266 fi
267 }
268
269
270 case "$group" in
271 battery)
272 case "$action" in
273 battery)
274 SwitchRunlevel
275 ;;
276 *)
277 logger "ACPI group battery / action $action is not defined"
278 ;;
279 esac
280 ;;
281
282 ac_adapter)
283 case "$action" in
284 ac_adapter)
285 SwitchRunlevel
286 ;;
287 *)
288 logger "ACPI group ac_adapter / action $action is not defined"
289 ;;
290 esac
291 ;;
292 *)
293 logger "ACPI group $group / action $action is not defined"
294 ;;
295 esac
296 </pre>
297
298 <p>
299 Give it a try: Plug AC in and out and watch syslog for the "Switching to AC
300 mode" or "Switching to battery mode" messages.
301 </p>
302
303 <p>
304 Due to the nature of the event mechanism, your laptop will boot into runlevel
305 <e>default</e> regardless of the AC/battery state. You can add another entry
306 to the boot loader with <c>softlevel=boot</c>, but it's likely to forget
307 choosing it. A better way is faking an ACPI event in the end of the boot
308 process and let the <path>/etc/acpi/default.sh</path> script decide whether a
309 runlevel change is necessary. Open <path>/etc/conf.d/local.start</path> in your
310 favourite editor and add these lines:
311 </p>
312
313 <pre caption="Runlevel switch at boot time by editing local.start">
314 <comment># Fake acpi event to switch runlevel if running on batteries</comment>
315 /etc/acpi/default.sh "battery/battery"
316 </pre>
317
318 <p>
319 Prepared like this you can activate Power Management policies for individual
320 devices.
321 </p>
322
323 </body>
324 </section>
325 </chapter>
326
327 <chapter>
328 <title>CPU Power Management</title>
329 <section>
330 <title>Setting the frequency manually</title>
331 <body>
332
333 <p>
334 Decreasing CPU speed and voltage has two advantages: On the one hand less
335 energy is consumed, on the other hand there is thermal improvement as your
336 system doesn't get as hot as running on full speed. The main disadvantage is
337 obviously the loss of performance. Decreasing processor speed is a trade off
338 between performance loss and energy saving.
339 </p>
340
341 <note>
342 Not every laptop supports frequency scaling. If unsure, have a look at the list
343 of supported processors in the <e>Troubleshooting</e> section to verify your's
344 is supported.
345 </note>
346
347 <p>
348 It's time to test whether CPU frequency changing works. To get comfortable with
349 the interface to the kernel, first do some manual speed modifications. To set
350 another CPU speed, use:
351 </p>
352
353 <pre caption="Manual CPU speed modifications">
354 <comment>(Get current frequency)</comment>
355 # <i>cat /proc/cpuinfo | grep "cpu MHz"</i>
356
357 <comment>(Lists supported frequencies. This might fail.)</comment>
358 # <i>cd /sys/devices/system/cpu/cpu0/cpufreq/</i>
359 # <i>cat scaling_available_frequencies</i>
360
361 <comment>(Change frequency to 1 GHz (1000000 KHz)
362 Replace with a frequency your laptop supports.)</comment>
363 # <i>echo -n userspace > scaling_governor</i>
364 # <i>echo -n 1000000 > scaling_setspeed</i>
365
366 <comment>(Verify frequency was changed)</comment>
367 # <i>cat /proc/cpuinfo | grep "cpu MHz"</i>
368 </pre>
369
370 <p>
371 If you are getting error messages, please refer to the <e>Troubleshooting</e>
372 chapter in the end of this guide.
373 </p>
374
375 <p>
376 You can also write to <path>scaling_max_freq</path> and
377 <path>scaling_min_freq</path> to set boundaries the frequency should stay in
378 between.
379 </p>
380
381 <note>
382 Some kernel seem to be buggy about updating <path>/proc/cpuinfo</path>. If you
383 don't see any change there, this doesn't neccessarily mean the CPU frequency
384 wasn't changed. If this happens to you, run <c>emerge x86info</c>, update your
385 kernel as asked and check the current frequency with <c>x86info -mhz</c>.
386 </note>
387
388 </body>
389 </section>
390 <section>
391 <title>Automated frequency adaption</title>
392 <body>
393
394 <p>
395 The above is quite nice, but not doable in daily life. Better let your system
396 set the appropriate frequency automatically. A couple of user space programs
397 like to do it for you. The following table gives a quick overview to help you
398 decide on one of them.
399 </p>
400
401 <table>
402 <tr>
403 <th>Name</th>
404 <th>Pro</th>
405 <th>Con</th>
406 </tr>
407 <tr>
408 <ti><uri link="http://mnm.uib.es/~gallir/cpudyn/">cpudyn</uri></ti>
409 <ti>Also supports disk standby</ti>
410 <ti></ti>
411 </tr>
412 <tr>
413 <ti><uri link="http://sourceforge.net/projects/cpufreqd/">cpufreq</uri></ti>
414 <ti>Sophisticated setup possible</ti>
415 <ti>Complicated setup</ti>
416 </tr>
417 <tr>
418 <ti><uri link="http://www.goop.org/~jeremy/speedfreq/">speedfreq</uri></ti>
419 <ti>
420 Small yet powerful<br />
421 Useful client/server interface
422 </ti>
423 <ti>Kernel 2.6 series only</ti>
424 </tr>
425 <tr>
426 <ti><uri link="http://www.deater.net/john/powernowd.html">powernowd</uri></ti>
427 <ti>Supports SMP</ti>
428 <ti></ti>
429 </tr>
430 </table>
431
432 <p>
433 While adjusting the frequency to the current load looks simple on the first
434 view, it's not such a trivial task. A bad algorithm can cause switching between
435 two frequencies all the time or wasting energy when setting frequency to an
436 unnecessary high level.
437 </p>
438
439 <p>
440 Which one to choose? If you have no idea about it, first try <c>speedfreq</c>:
441 </p>
442
443 <pre caption="Installing speedfreq">
444 # <i>emerge speedfreq</i>
445 # <i>rc-update add speedfreq battery</i>
446 </pre>
447
448 <p>
449 <c>speedfreq</c> can be configured by editing
450 <path>/etc/conf.d/speedfreq</path>. For example, if you like users to be able
451 to change the policy, modify <c>SPEEDFREQ_OPTS=""</c> to
452 <c>SPEEDFREQ_OPTS="-u"</c>. Having done your changes, start the daemon.
453 </p>
454
455 <pre caption="Starting speedfreq">
456 # <i>/etc/init.d/speedfreq start</i>
457 </pre>
458
459 <p>
460 Setting up cpufreq is a little bit more complicated.
461 </p>
462
463 <warn>
464 Do not run more than one of the above programs at the same time. It may cause
465 confusion like switching between two frequencies all the time. If you just
466 installed speedfreq, skip cpufreq now.
467 </warn>
468
469 <pre caption="Installing cpufreqd">
470 # <i>emerge cpufreqd</i>
471 # <i>rc-update add cpufreqd battery</i>
472 </pre>
473
474 <p>
475 <c>cpufreqd</c> comes with a default configuration in
476 <path>/etc/cpufreqd.conf</path>.
477 Change the config file to fit your needs. The following will save more energy
478 than the default one - at the cost of less performance, of course.
479 </p>
480
481 <pre caption="A sample cpufreqd config file">
482 [General]
483 pidfile=/var/run/cpufreqd.pid
484 poll_interval=2
485 pm_type=acpi
486 <comment># Uncomment the following line to enable ACPI workaround (see cpufreqd.conf(5))
487 # acpi_workaround=1</comment>
488 verbosity=4 <comment>#(if you want a minimal logging set to 5)</comment>
489
490 <comment># Full performance</comment>
491 [Profile]
492 name=ac
493 minfreq=600000
494 maxfreq=1400000
495 policy=performance
496
497 <comment># Maximum power saving</comment>
498 [Profile]
499 name=battery
500 minfreq=600000
501 maxfreq=900000
502 policy=powersave
503
504 <comment># Constant frequency</comment>
505 [Profile]
506 name=dvd
507 minfreq=900000
508 maxfreq=1100000
509 policy=powersave
510
511 <comment># Full performance when running on AC</comment>
512 [Rule]
513 name=ac_on
514 ac=on
515 profile=ac
516
517 <comment># Compiling should be fast if battery state is ok</comment>
518 [Rule]
519 name=compiling
520 ac=off
521 battery_interval=30-100
522 programs=emerge,make,gcc,cpp
523 cpu_interval=0-100
524 profile=ac
525
526 <comment># watching DVD's gets sluggish with slow CPU frequency
527 # Can also be used for games etc.</comment>
528 [Rule]
529 name=dvd_watching
530 ac=off
531 battery_interval=15-100
532 programs=xine,mplayer,avidemux,kaffeine,kmplayer
533 cpu_interval=0-100
534 profile=dvd
535
536 <comment># If above doesn't apply, maximise power saving</comment>
537 [Rule]
538 name=battery_on
539 ac=off
540 battery_interval=0-100
541 cpu_interval=0-100
542 profile=battery
543 </pre>
544
545 <p>
546 <c>cpudyn</c> and <c>powernowd</c> are installed in the same way as
547 <c>speedfreq</c>.
548 </p>
549
550 <p>
551 The last thing to check is that your new policies do a good job. An easy way to
552 do so is monitoring the CPU speed while working with your laptop:
553 </p>
554
555 <pre caption="Monitoring CPU speed">
556 # <i>watch -n 1 cat /proc/cpuinfo | grep "cpu MHz"</i>
557 </pre>
558
559 <p>
560 If <path>/proc/cpuinfo</path> doesn't get updated (see above), monitor the CPU
561 frequency with:
562 </p>
563
564 <pre caption="Alternative CPU speed monitoring">
565 # <i>watch -n 1 x86info -mhz</i>
566 </pre>
567
568 <p>
569 Depending on your setup, CPU speed should increase on heavy load, decrease on
570 no activity or just stay at the same level.
571 </p>
572
573 </body>
574 </section>
575 </chapter>
576
577 <chapter>
578 <title>LCD Power Management</title>
579 <section>
580 <title>Energy consumer no. 1</title>
581 <body>
582
583 <p>
584 As you can see in <uri link="doc_chap1_fig1">figure 1.1</uri>, the LCD display
585 consumes the biggest part of energy (might not be the case for non-mobile
586 CPU's). Thus it's quite important not only to shut the display off when not
587 needed, but also to reduce it's backlight if possible. Most laptops offer the
588 possibility to control the backlight dimming.
589 </p>
590
591 <p>
592 First thing to check is the standby/suspend/off timings of the display. As this
593 depends heavily on your windowmanager, I'll let you figure it out yourself.
594 Just two common places: Blanking the terminal can be done with <c>setterm
595 -blank &lt;number-of-minutesM&gt;</c>, <c>setterm -powersave on</c> and
596 <c>setterm -powerdown &lt;number-of-minutesM&gt;</c>.
597 For Xorg, modify <path>/etc/X11/xorg.conf</path> similar to this:
598 </p>
599
600 <pre caption="LCD suspend settings in Xorg and XFree86">
601 Section "ServerLayout"
602 Identifier [...]
603 [...]
604 Option "BlankTime" "5" <comment># Blank the screen after 5 minutes (Fake)</comment>
605 Option "StandbyTime" "10" <comment># Turn off screen after 10 minutes (DPMS)</comment>
606 Option "SuspendTime" "20" <comment># Full suspend after 20 minutes</comment>
607 Option "OffTime" "30" <comment># Turn off after half an hour</comment>
608 [...]
609 EndSection
610
611 [...]
612
613 Section "Monitor"
614 Identifier [...]
615 Option "DPMS" "true"
616 [...]
617 EndSection
618 </pre>
619
620 <p>
621 This is the same for XFree86 and <path>/etc/X11/XF86Config</path>.
622 </p>
623
624 <p>
625 Probably more important is the backlight dimming. If you have access to the
626 dimming settings via a tool, write a small script that dims the backlight in
627 battery mode and place it in your <e>battery</e> runlevel.
628 </p>
629
630 </body>
631 </section>
632 </chapter>
633
634 <chapter>
635 <title>Disk Power Management</title>
636 <section>
637 <title>Sleep when idle</title>
638 <body>
639
640 <p>
641 Let's bring the hard disk to sleep as early as possible whenever it is not
642 needed. I'll show you two possibilities to do it. First <c>cpudyn</c> supports
643 Disk Power Management. Uncomment the lines in the "Disk Options" section in
644 <path>/etc/conf.d/cpudyn</path>. To put your first disk to sleep after 60
645 seconds of no activity, you would modify it like this:
646 </p>
647
648 <pre caption="Using cpudyn for disk standby">
649 <comment>################################################
650 # DISK OPTIONS
651 # (disabled by default)
652 ################################################
653
654 #
655 # Timeout to put the disk in standby mode if there was no
656 # io during that period (in seconds)
657 #
658 </comment>
659 TIMEOUT=60
660 <comment>
661 #
662 # Specified disks to spindown (comma separated devices)
663 #
664 </comment>
665 DISKS=/dev/hda
666 </pre>
667
668 <p>
669 The second possibility is using a small script and hdparm. Create
670 <path>/etc/init.d/pm.hda</path> like this:
671 </p>
672
673 <pre caption="Using hdparm for disk standby">
674 #!/sbin/runscript
675 start() {
676 ebegin "Activating Power Management for Hard Drives"
677 hdparm -q -S12 /dev/hda
678 eend $?
679 }
680
681 stop () {
682 ebegin "Deactivating Power Management for Hard Drives"
683 hdparm -q -S253 /dev/hda
684 eend $?
685 }
686 </pre>
687
688 <p>
689 See <c>man hdparm</c> for the options. If your script is ready, add it to the
690 battery runlevel.
691 </p>
692
693 <pre caption="Automate disk standby settings">
694 # <i>/sbin/depscan.sh</i>
695 # <i>rc-update add pm.hda battery</i>
696 </pre>
697
698 <impo>
699 Be careful with sleep/spin down settings of your hard drive. Setting it to
700 small values might wear out your drive and lose warranty.
701 </impo>
702
703 </body>
704 </section>
705 <section>
706 <title>Increasing idle time - laptop-mode</title>
707 <body>
708
709 <p>
710 Recent kernels (2.6.6 and greater, recent 2.4 ones and others with patches)
711 include the so-called <e>laptop-mode</e>. When activated, dirty buffers are
712 written to disk on read calls or after 10 minutes (instead of 30 seconds). This
713 minimizes the time the hard disk needs to be spun up.
714 </p>
715
716 <p>
717 <!-- FIXME: bug #45593 -->
718 To start and stop laptop-mode, create a script /etc/init.d/laptop-mode. You can
719 take the one included in
720 <path>/usr/src/linux/Documentation/laptop-mode.txt</path>. Onces it's ready,
721 make sure it gets called.
722 </p>
723
724 <pre caption="Automatic start of laptop-mode">
725 # <i>rc-update add laptop-mode battery</i>
726 </pre>
727
728 <warn>
729 Once again: Be careful with sleep/spin down settings of your hard drive.
730 Setting it to small values might wear out your drive and lose warranty. Be sure
731 to read the documentation in laptop-mode.txt. Make sure to stop laptop-mode
732 before your battery runs out of power and data gets written to disk - otherwise
733 you will at least lose the last 10 minutes of your work.
734 </warn>
735
736 </body>
737 </section>
738 <section>
739 <title>Other tricks</title>
740 <body>
741
742 <p>
743 Besides putting your disk to sleep state as early as possible, it is a good
744 idea to minimize disk accesses. Have a look at processes that write to your
745 disk frequently - the syslogd is a good candidate. You probably don't want to
746 shut it down completely, but it's possible to modify the config file so that
747 "unnecessary" things don't get logged and thus don't create disk traffic. Cups
748 writes to disk periodically, so consider shutting it down and only enable it
749 manually when needed.
750 </p>
751
752 <pre caption="Disabling cups in battery mode">
753 # <i>rc-update del cupsd battery</i>
754 </pre>
755
756 <p>
757 Another possibility is to deactivate swap in battery mode. Before writing a
758 swapon/swapoff switcher, make sure there is enough RAM and swap isn't used
759 heavily, otherwise you'll be in big problems.
760 </p>
761
762 <p>
763 If you don't want to use laptop-mode, it's still possible to minimize disk
764 access by mounting certain directories as <e>tmpfs</e> - write accesses are not
765 stored on a disk, but in main memory and get lost with unmounting. Often it's
766 useful to mount <path>/tmp</path> like this - you don't have to pay special
767 attention as it gets cleared on every reboot regardless whether it was mounted
768 on disk or in RAM. Just make sure you have enough RAM and no program (like a
769 download client or compress utility) needs extraordinary much space in
770 <path>/tmp</path>. To activate this, enable tmpfs support in your kernel and
771 add a line to <path>/etc/fstab</path> like this:
772 </p>
773
774 <pre caption="Editing /etc/fstab to make /tmp even more volatile">
775 none /tmp tmpfs size=32m 0 0
776 </pre>
777
778 <warn>
779 Pay attention to the size parameter and modify it for your system. If you're
780 unsure, don't try this at all, it can become a perfomance bottleneck easily. In
781 case you want to mount <path>/var/log</path> like this, make sure to merge the
782 log files to disk before unmounting. They are essential. Don't attempt to mount
783 /var/tmp like this. Portage uses it for compiling...
784 </warn>
785
786 </body>
787 </section>
788 </chapter>
789
790 <chapter>
791 <title>Power Management for other devices</title>
792 <section>
793 <title>Wireless Power Management</title>
794 <body>
795
796 <p>
797 Wireless LAN cards consume quite a few energy. Put them in Power Management
798 mode in analogy to the pm.hda script.
799 </p>
800
801 <pre caption="WLAN Power Management automated">
802 #!/sbin/runscript
803 start() {
804 ebegin "Activating Power Management for Wireless LAN"
805 iwconfig wlan0 power on power max period 3
806 eend $?
807 }
808
809 stop () {
810 ebegin "Deactivating Power Management for Wireless LAN"
811 iwconfig wlan0 power off
812 eend $?
813 }
814 </pre>
815
816 <p>
817 Starting this script will put wlan0 in Power Management mode, going to sleep at
818 the latest three seconds after no traffic.
819 Save it as <path>/etc/init.d/pm.wlan0</path> and add it to the battery runlevel
820 like the disk script above. See <c>man iwconfig</c> for details and more
821 options. If your driver and access point support changing the beacon time, this
822 is a good starting point to save even more energy.
823 </p>
824
825 </body>
826 </section>
827 <section>
828 <title>USB Power Management</title>
829 <body>
830
831 <p>
832 There are two problems with USB devices regarding energy consumption: First,
833 devices like USB mice, digital cameras or USB sticks consume energy while
834 plugged in. You cannot avoid this (nevertheless remove them in case they're not
835 needed). Second, when there are USB devices plugged in, the USB host controller
836 periodically accesses the bus which in turn prevents the CPU from going into
837 C3/4 sleep mode. The OS answer to this problem is the so called "USB selective
838 suspend", which has not yet been implemented in the kernel. USB selective
839 suspend only allows bus accesses in case the device is in use. The cruel
840 workaround until it's implemented is as following: Compile USB support and
841 devices as modules and remove them via a script while they are not in use (e.g.
842 when closing the lid).
843 </p>
844
845 </body>
846 </section>
847 </chapter>
848
849 <chapter>
850 <title>Sleep states: sleep, standby, suspend to disk</title>
851 <section>
852 <title>Overview</title>
853 <body>
854
855 <p>
856 ACPI defines different sleep states. The more important ones are
857 </p>
858
859 <ul>
860 <li>S1 aka Standby</li>
861 <li>S3 aka Suspend to RAM aka Sleep</li>
862 <li>S4 aka Suspend to Disk aka Hibernate</li>
863 </ul>
864
865 <p>
866 They can be called whenever the system is not in use, but a shutdown is not
867 wanted due to the long boot time.
868 </p>
869
870 </body>
871 </section>
872 <section>
873 <title>Sleep, Standby &amp; Hibernate</title>
874 <body>
875
876 <p>
877 The ACPI support for these sleep states is marked as experimental for good
878 reason. APM sleep states seem to be more stable, however you can't use APM and
879 ACPI together.
880 </p>
881
882 <warn>
883 Altough sleep state support is improving much, it's still rather experimental.
884 At last I got swsusp2 and suspend to RAM to work, but be warned: This will very
885 likely not work but damage your data/system.
886 </warn>
887
888 <p>
889 There are currently three implementations for S4. The original one is swsusp,
890 then there is swsusp2 which has the nicest interface (including bootsplash
891 support), but requires manual kernel patching. Last not least we have
892 Suspend-to-Disk, a fork of swsusp.
893 </p>
894
895 <p>
896 If this confused you, have a look at a <uri
897 link="http://softwaresuspend.berlios.de/features.html#compare">feature
898 comparison</uri>. If you still are confused and don't know which one to choose,
899 first give swsusp2 a try, it looks most promising.
900 </p>
901
902 <p>
903 The kernel part for this is as following:
904 </p>
905
906 <pre caption="Kernel configuration for the various suspend types">
907 Power Management Options ---&gt;
908
909 <comment>(sleep and standby)</comment>
910 ACPI( Advanced Configuration and Power Interface ) Support --->
911 [*] ACPI Support
912 [*] Sleep States
913
914 <comment>(hibernate with swsusp)</comment>
915 [*] Software Suspend (EXPERIMENTAL)
916
917 <comment>(hibernate with swsusp2)</comment>
918 Software Suspend 2
919 --- Image Storage (you need at least one writer)
920 [*] Swap Writer
921 --- Page Transformers
922 [*] LZF image compression
923 (/dev/"your-swap-here") Default resume device name
924
925 <comment>(hibernate with Suspend-to-Disk)</comment>
926 [*] Suspend-to-Disk Suport
927 (/dev/"your-swap-here") Default resume partition
928 </pre>
929
930 <p>
931 Compile your kernel with the appropriate options enabled and issue <c>cat
932 /proc/acpi/sleep</c> for 2.4 series respectively <c>cat /sys/power/state</c>
933 for 2.6 to find out what is supported. The latter gives me <c>standby mem
934 disk</c>. For swsusp, the kernel parameter <c>resume=/dev/"your-swap-here"</c>
935 has to be appended. If booting is not possible due to a broken image, use
936 <c>noresume</c> for swsusp, <c>pmdisk=off</c> for Suspend-to-Disk and
937 <c>noresume2</c> for swsusp2.
938 </p>
939
940 <p>
941 To put your system in one of the sleep states, use
942 </p>
943
944 <pre caption="Activating sleep states">
945 <comment>(kernel 2.4 series)</comment>
946 # <i>echo 1 &gt; /proc/acpi/sleep</i> <comment>(standby)</comment>
947 # <i>echo 3 &gt; /proc/acpi/sleep</i> <comment>(sleep)</comment>
948
949 <comment>(kernel 2.6 series)</comment>
950 # <i>echo -n standby &gt; /sys/power/state</i> <comment>standby</comment>
951 # <i>echo -n mem &gt; /sys/power/state</i> <comment>sleep</comment>
952
953 <comment>(swsusp)</comment>
954 # <i>echo 4 &gt; /proc/acpi/sleep</i> <comment>hibernate</comment>
955
956 <comment>(Suspend-to-Disk)</comment>
957 # <i>echo -n disk &gt; /sys/power/state</i> <comment>hibernate</comment>
958
959 <comment>(swsusp2)</comment>
960 # <i>echo &gt; /proc/swsusp/activate</i>
961 </pre>
962
963 <warn>
964 Backup your data before doing this. Run <c>sync</c> before executing one of the
965 commands to have cached data written to disk. First try it outside of X, then
966 with X running, but not logged in.
967 </warn>
968
969 <p>
970 If you experience kernel panics due to uhci or similar, try to compile USB
971 support as module and unload the modules before sending your laptop to sleep
972 mode.
973 </p>
974
975 <p>
976 While the above should be sufficient to get swsusp and Suspend-to-Disk running
977 (I didn't say working), swsusp2 needs special care.
978 The first thing to do is to patch the kernel with the patches provided at <uri
979 link="http://softwaresuspend.berlios.de/">
980 http://softwaresuspend.berlios.de/</uri>. Afterwards, install the hibernate
981 script from the same page.
982 </p>
983
984 </body>
985 </section>
986 </chapter>
987
988 <chapter>
989 <title>Troubleshooting</title>
990 <section>
991 <title>If things go wrong...</title>
992 <body>
993
994 <p>
995 <e>Q:</e> I'm trying to change the CPU frequency, but
996 <path>/sys/devices/system/cpu/cpu0/cpufreq/scaling_governor</path> does not
997 exist.
998 </p>
999
1000 <p>
1001 <e>A:</e> Make sure your processor supports CPU frequency scaling and you chose
1002 the right CPUFreq driver for your processor. Here is a list of processors that
1003 are supported by cpufreq (kernel 2.6.7): ARM Integrator, ARM-SA1100,
1004 ARM-SA1110, AMD Elan - SC400, SC410, AMD mobile K6-2+, AMD mobile K6-3+, AMD
1005 mobile Duron, AMD mobile Athlon, AMD Opteron, AMD Athlon 64, Cyrix Media GXm,
1006 Intel mobile PIII and Intel mobile PIII-M on certain chipsets, Intel Pentium 4,
1007 Intel Xeon, Intel Pentium M (Centrino), National Semiconductors Geode GX,
1008 Transmeta Crusoe, VIA Cyrix 3 / C3, UltraSPARC-III, SuperH SH-3, SH-4, several
1009 "PowerBook" and "iBook2" and various processors on some ACPI 2.0-compatible
1010 systems (only if "ACPI Processor Performance States" are available to the
1011 ACPI/BIOS interface).
1012 </p>
1013
1014 <p>
1015 <e>Q:</e> My laptop supports frequency scaling, but
1016 <path>/sys/devices/system/cpu/cpu0/cpufreq/</path> is empty.
1017 </p>
1018
1019 <p>
1020 <e>A:</e> Look for ACPI related error messages with <c>dmesg | grep ACPI</c>.
1021 Try to update the BIOS, especially if a broken DSDT is reported. You can also
1022 try to fix it yourself (which is beyond the scope of this guide).
1023 </p>
1024
1025 <p>
1026 <e>Q:</e> My laptop supports frequency scaling, but according to /proc/cpuinfo
1027 the speed never changes.
1028 </p>
1029
1030 <p>
1031 <e>A:</e> This seems to be a kernel bug. Run <c>emerge x86info</c>, update your
1032 kernel as asked and check the current frequency with <c>x86info -mhz</c>.
1033 </p>
1034
1035 <p>
1036 <e>Q:</e> I can change the CPU frequency, but the range is not as wide as in
1037 another OS.
1038 </p>
1039
1040 <p>
1041 <e>A:</e> You can combine frequency scaling with ACPI throttling to get a lower
1042 minimum frequency. Notice that throttling doesn't save much energy and is
1043 mainly used for thermal management (keeping your laptop cool and quiet). You
1044 can read the current throttling state with <c>cat
1045 /proc/acpi/processor/CPU/throttling</c> and change it with <c>echo -n "0:x" >
1046 /proc/acpi/processor/CPU/limit</c>, where x is one of the Tx states listed in
1047 <path>/proc/acpi/processor/CPU/throttling</path>.
1048 </p>
1049
1050 <p>
1051 <e>Q:</e> Battery life time seems to be worse than before.
1052 </p>
1053
1054 <p>
1055 <e>A:</e> Check your BIOS settings. Maybe you forgot to re-enable some of the
1056 settings.
1057 </p>
1058
1059 <p>
1060 <e>Q:</e> My battery is charged, but KDE reports there would be 0% left and
1061 immediately shuts down.
1062 </p>
1063
1064 <p>
1065 <e>A:</e> Check that battery support is compiled into your kernel. If you use
1066 it as a module, make sure the module is loaded.
1067 </p>
1068
1069 <p>
1070 <e>Q:</e> I have a Dell Inspiron 51XX and I don't get any ACPI events.
1071 </p>
1072
1073 <p>
1074 <e>A:</e> This seems to be a kernel bug. Read on <uri
1075 link="http://bugme.osdl.org/show_bug.cgi?id=1752">here</uri>.
1076 </p>
1077
1078 <p>
1079 <e>Q:</e> I just bought a brand new battery, but it only lasts for some
1080 minutes! What am I doing wrong?
1081 </p>
1082
1083 <p>
1084 <e>A:</e> First follow your manufacturer's advice on how to charge the battery
1085 correctly.
1086 </p>
1087
1088 <p>
1089 <e>Q:</e> The above didn't help. What should I do then?
1090 </p>
1091
1092 <p>
1093 <e>A:</e> Some batteries sold as "new" are in fact old ones. Try the following:
1094 </p>
1095
1096 <pre caption="Querying battery state">
1097 $ <i>grep capacity /proc/acpi/battery/BAT0/info</i>
1098 design capacity: 47520 mWh
1099 last full capacity: 41830 mWh
1100 </pre>